Testers

NX Hipot Plus

By February 21, 2019 October 5th, 2023 No Comments

NX Hipot+

NX-Hipot-Tester-and-nxhipot-combo
Dynalab NX Hipot
Dynalab NX Hipot Tester
Hipot+ Exp front
  • 1000VAC/1500VDC Hipot Testing
  • Stand-alone operation
  • Supports network file transfer and reporting
  • Accurate component testing
  • Keyed security access
  • Built for rough industrial environments
  • Tests up to 2,048 test points

The Dynalab NX Hipot Tester is an economical, feature-rich, stand-alone wire harness tester offering up to 2,048 test points. The powerful NX Editor software application is used to create unique program files to successfully validate all electrical and electro-mechanical wire harness parameters. This tester is compatible with all Dynalab NX accessories such as printers, scanners, control ports, and much more. The NX Hipot Tester supports network communications with the NX Server for efficient file transfers and advanced data collection.

For test applications that span the range from simple to complex, Dynalab’s NX Testers offer more features than the competition at a lower price!

ItemSpecifications
Hipot Range50 VDC – 1500 VDC (± 5%, ± 5 VDC)
50 VAC – 1000 VAC (± 5%, ± 10 VAC) (Optional, specify with "-AC" suffix)
Insulation Resistance Range5 MΩ – 1 GΩ (± 10%)
ConnectionsContinuity:
0.1 Ω - 10 Ω (±0.1Ω)
10 Ω - 500KΩ (±1%)
500KΩ - 2MΩ (±5%)

Shorts:
1KΩ - 2MΩ (± 20%)
ComponentsResistors:
0.1 Ω -10 Ω (±0.1Ω)
10 Ω - 500KΩ (±1%)
500KΩ - 2MΩ (±5%)

Diodes:
Checks for proper orientation

Capacitors:
100pF - 100,000uF (±2% to ±20%, ±10pF based on capacitor type)
4-Wire (Kelvin) Mode0.005 Ω - 100 Ω (±1%, ±0.005 Ω)
Relay TestingCapable of active relay testing
Testing MethodUtilizes proprietary electronic switching circuits designed to validate connections from NX Editor program data.
Test VoltageTest voltage is defined by the NX Tester for optimum resistance measurements. The voltage will not exceed 14VDC and cannot be configured by the user.
Test CurrentTest current is defined by the NX Tester for optimum measurements. The current will not exceed 5mA DC and cannot be configured by the user.
Test Speed1 seconds per 1024 test points (continuity only)
3 seconds per 1024 test points (continuity and shorts)
9 seconds per 128 test points (Hipot)
DisplayErrors are displayed using connector names, wire names, and wire color on a 4-line x 20 character display.
Audible TonesProvides a variety of user programmable tones for error notification and special events.
Program StorageApproximately 150 to 250 test programs containing under 256 test points. File storage will be reduced with programs that contain higher test point counts. 3.3MB Internal Memory Size.
Control PortConnects the optional Control Port Module for controlling two outputs and monitoring one input.
Serial PortsTwo RS-232 serial ports for connecting printers, bar code scanners, extended displays or the Modular Control System. Two additional RS-232 ports are available with the optional Communication Board.
Network PortNetwork port to allow communication to the NX Server for program file transfers and advanced reporting. Available with the optional Communication Board (100 Mbps).
Test Point InterfaceDIN Connector (96 Position, 32 Loaded)
Input PowerUses external power supply rated for 100 – 240VAC, 50-60Hz, 30W max. Power supply provides 15VDC to the NX Tester.
Test Point Capacity64 - 2048 test points (64 test point increments)
Size (W x D x H)Display Unit: 10.7” x 2” x 3.8” (27.2 cm x 5.1 cm x 9.7 cm)
Base Unit: 9.5” x 6.4” x 8.6” (24.2 cm x 16.3 cm x 21.9 cm)
Expansion Unit: 9.5” x 6.4” x 6.1” (24.2 cm x 16.3 cm x 15.5 cm)
WeightDisplay Unit: 2.5 lbs (1.2 Kg)
Base Unit: 13.8 lbs (6.3 Kg)
Expansion Unit: 9.8 lbs (4.5 Kg)
Operating ParametersTemperature: 32– 122 degrees F (0– 50 degrees Celsius)
Humidity: 75% non-condensing
WarrantyOne year parts and labor
CertificationsCE Certified

Hipot Discrete Wire Cable Assembly

The Hipot Discrete Wire Cable Assembly consists of 32 individual 22 AWG wires, 6 feet (1.8 m) long, ready to be connected to a fixture board. Learn More

Hipot Discrete Wire Connector

Hipot Discrete Wire Connectors can be used to build your own interface cables with customer supplied wires. Solder terminals, no tooling required. Learn More

Hipot test point board

Hipot Test Point Board

Each NX Hipot Test Point Board provides an additional 64 test points for any NX Hipot Tester. 5-4006

Communication Board

Communication Board Kit

Adds two additional RS-232 serial ports to connect to a printer or scanner, and one network port (100 Mbps) to connect to the NX Server.  Part Number: 5-4011

Hipot Expansion Unit

Provides the ability to accommodate 8 additional test point boards for an NX Hipot+ Tester. Learn more

Enhance the NX Tester’s graphics and reporting capabilities with the NX View software application.

NX View
NX View
Reporting

Select the part number below that corresponds to the quantity of test points required (How to calculate?)

Part #Description
7-0256-0NX Hipot+ Tester with 256 Test Points
7-0512-0NX Hipot+ Tester with 512 Test Points
7-0768-0NX Hipot+ Tester with 768 Test Points
7-1024-0NX Hipot+ Tester with 1024 Test Points

Change part number to specify test point quantity in 64 point increments (i.e., 7-1536-0 contains 1,536 test points)

1000 VAC Hipot Option
To order this option, add -AC to the end of the part number (i.e. 7-256-0-AC).
Communications Board Option
Adds two additional RS-232 serial ports to connect to a printer or scanner, and one network port to connect to the NX Server. To order a tester with this option, replace the last digit of the part number with "1" (i.e. 7-0512-1).
NX View Software
Software application that enhances the user experience with additional information, graphics, program storage and reporting. Learn More