Overview


Reporting

The NX Server provides the additional capability of collecting reports from NX Testers and storing the data in a Relational database. In addition to the suite of standard reports that are provided with the NX Server Enterprise Edition, the customer may choose to develop custom reports using SQL-based reporting tools.

The Reports View displays the following standard reporting options:

  • Product Detail
  • Provides a list of individual reports for a specified range of dates and testers
  • Summary by Product
  • Provides a summarized view of cycle times, units good, and units failed by program name and part number for a specified range of dates.
  • Summary by Tester
  •  
    Provides a summarized view of cycle times, units good, and units failed by program name and part number for a specified range of dates and testers.


    Product Detail Report

    The Product Detail Report displays every report sent by each selected NX Tester during the specified time frame:

    Each line of the Product Detail Report corresponds to a single report transmitted by an NX Tester to the NX Server. Information about a report is displayed on a single horizontal line, organized into 6 columns:

    Program Name: The name of the program
    Part #: The part number
    Tester Serial: The serial number of the NX Tester
    Cycle Time: The cycle time as reported in the NX Tester’s counter variable $PC8
    Errors: The number of errors reported
    Report Date/Time: The date and time the report was transmitted to the NX Server.

    Clicking on any Report Date/Time will display the Product Connections report for the selected timestamp:



    The Product Connections report displays the test results for one wire harness. Each line of the Product Connections Report corresponds to a wire, component, or detection switch in the wire harness, organized into 10 columns:

    Type: The type of test (Wire, Diode, Resistor, Capacitor).
    Point: The two connection points for the test.
    Name: The wire name.
    Color: The wire color.
    Set: The expected value.
    Actual: The measured value.
    Tolerance: If the line corresponds to a Resistor, Capacitor, or Generic Component, this column displays the tolerance.
    Miswired: Contains an X if the connection is miswired.
    Failed: Contains an X if the test for this line item failed.

    Summary by Product Report

    The Summary by Product report provides a summarized view of cycle times, units good, and units failed by program name and part number for a specified range of dates:

    Each line of the Summary by Product report corresponds to a unique combination of Program Name and Part #. Summary information about each Program Name / Part # combination is displayed on a single horizontal line organized into 8 columns:

    Program Name: The name of the program.
    Part #: Part number if defined.
    Avg. Cycle: The average cycle time in seconds.
    Min. Cycle: The minimum cycle time in seconds.
    Max Cycle: The maximum cycle time in seconds
    Units Failed: The number of testers that failed.
    Units Good: The number of testers that passed.
    Total Units: The total number of testers.

    Summary by Tester Report

    The Summary by Tester report provides a summarized view of cycle times, units good, and units failed by program name and part number for a specified range of dates and testers:



    Each line of the Summary by Tester report corresponds to a unique combination of Tester Serial Number, Program Name and Part #. Summary information is displayed on a single horizontal line organized into 9 columns:

    Tester Serial: The NX Tester serial number.
    Program Name: The name of the program.
    Part #: The part number.
    Avg. Cycle: The average cycle time in seconds.
    Min. Cycle: The minimum cycle time in seconds.
    Max Cycle: The maximum cycle time in seconds
    Units Failed: The number of testers that failed.
    Units Good: The number of testers that passed.
    Total Units: The total number of testers.